TinyMicro control unit

Design the control unit of the TinyMicro.

Specification

    module control_unit (Instruction, Instruction_Address, EnA, EnB, Op,
                         ReadWrite, MemConst, MemALU, Zero, Positive, Const,
                         clk, rst);
        input [7:0] Instruction;
        output [5:0] Instruction_Address;
        output [1:0] Op;
        output [7:0] Const;
        output EnA, EnB, ReadWrite, MemConst, MemALU;
        input Zero, Positive;
        input clk, rst;

Input

- Instruction is the instruction coming from the instruction memory.

- Zero is the signal that is asserted when the zero condition for a jump
  is true.

- Positive is the signal that is asserted when the positive condition
  for a jump is true.

- clk is the clock signal of the circuit.

- rst is the reset signal of the circuit.

Output

- Instruction_Address is the address sent to the instruction memory
  (program counter).

- Op indicates the type of operation for ALU instructions.

- Const is the constant encoded in instruction register (sign-extended
  up to 8 bits).

- EnA and EnB are the signals that enable writing into registers RA ad
  RB, respectively.

- ReadWrite is the signal the indicates whether to read (0) from or
  write (1) into data memory.

- MemConst is the signal that controls the datapath multiplexer
  selecting between data memory (0) and constant from the instruction
  register (1).

- MemALU is the signal that controls the datapath multiplexer selecting
  between memory/constant (0) and the ALU output (1).

Problem information

Author: Jordi Cortadella

Generation: 2026-02-03T12:25:15.001Z

© Jutge.org, 2006–2026.